IJNR 2016, 11(1): 87-94 Back to browse issues page
The determining of conformity rate of nursing cares regarding to respiratory system in neonates under mechanical ventilation in NICU
Z Jafari , L Khanali Mojen * , M Rassouli , A.R Baghestani , A.R Gahri Sarabi , A Shirinabady Farahani , H Shiri
Shahid Beheshti University of Medical Sciences, Tehran, Iran. , leilakhanali@yahoo.com
Abstract:   (11217 Views)

Introduction: Nurses are in a unique position to have a positive effect on an infant's ventilation therapy and complications protection because they maintain a continuous presence at the infants’ bedside and perform related tasks. Thus this study was done aimed to determine the conformity rate of nursing cares regarding to respiratory system in neonates under mechanical ventilation in neonatal intensive units(NICU) with the standards. Method: In this cross-sectional descriptive study, 100 nursing care regarding to respiratory system were observed by time sampling and event sampling. Data collected using a checklist included standard cares regarding to respiratory care, which was developed according to existing standards. Content Validity Index (0.95) and inter rater coefficient reliability (ICC=0.98), were calculated for checklist. Data collection method was observation and docomentation of checklist’s items which carried out in NICU of Mahdiyeh, Mofid and Emam Hosein hospitals affiliated to Shahid Beheshti University of Medical Science. Data were analyzed through descriptive statistics using SPSS software version 21. Results: Conformity rate of nursing cares regarding to respiratory system in neonates under mechanical ventilation in NICU with developed standards, was evaluated 59.27 percents and quality of nursing cares was moderate. The most of the conformity rate with standars (94%) conformiting of ventilator setting with doctors’ orders and documenting its’ amounts and the lowest (1%) correct adjusting of SPO2 alarm limit was evaluated. Conclusion: According to Nursing cares regarding to repiratory system are the most common cares and results indicated moderate level in compare with standars thus Authorities should pay attention to causes of noncomformity with standard cares and eliminate them for increasing health of hospitalized neonates, decrease complications and followed it, decrease length of stay as well as costs.

Keywords: conformity with standards, nursing care, respiratory system, mechanical ventilation
Full-Text [PDF 217 kb]   (2695 Downloads)    
Type of Study: Medical Surgical Nursing | Subject: nursing
Received: 2016/03/5 | Accepted: 2016/09/5 | Published: 2016/09/5
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jafari Z, Khanali Mojen L, Rassouli M, Baghestani A, Gahri Sarabi A, Shirinabady Farahani A et al . The determining of conformity rate of nursing cares regarding to respiratory system in neonates under mechanical ventilation in NICU . IJNR 2016; 11 (1) :87-94
URL: http://ijnr.ir/article-1-1675-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 11, Issue 1 ( March-April 2016) Back to browse issues page
Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4645